Call: (203) 908-3323

Fax: (203) 908-3325

109 Holland Avenue, Bridgeport, CT 06605 USA



Home
Transfer Pumps
Fuel Oil Pump Sets
Day Tanks
Fuel Polishing
EF Catalog
Tank Fill Systems
About Us
Contact Us
Support Request

Manual Day Tanks



Phillips single wall (PDT) and double wall (PDWT)
series day tanks provide a ready supply of oil or diesel
fuel for boilers, diesel generators, or other stationary,
engine-driven or burner-fired equipment.  With capacities
ranging from 25 to 650 gallons, Phillips Pump day tanks
may be selected for maximum fuel capacity for placement
in a minimum amount of space.

All tanks are manufactured in accordance with a UL 142
label and meet NFPA 30 standards.  Each Phillips Pump
day tank is constructed from 10 gauge steel, seam welded
to provide long lasting life in rugged industrial and commercial
environments.

Each tank is pressure tested with a 5 PSI rating, and has
an internal epoxy coating with an external chemical-resistant
enamel finish over a rust-resistant primer.

Our PDT series single wall day tank or our PDWT series double
wall day tank includes a mechanical gauge as a visual level
indicator, a UL sized standard and emergency vent port, 2" NPT manual fill port, 1" NPT tank fill ports, generator supply, generator return, overflow and drain ports. Our PDWT series double wall daytank also includes a rupture basin standard and emergency vent port.


Features Include:

  • Heavy gauge, seam welded, reinforced steel tank with heavy gauge steel channel support base with mounting holes
  • Mechanical tank gauge for visual level indication
  • Corrosion-resistant internal epoxy coated
  • Complete array of fittings and connections
  • Generator supply and pump supply or return ports supplied with drop tubes
  • Either 150% and 200% optional rupture containment basins are available for the single wall daytanks. Our PDWT series double wall daytank comes complete with closed top 135% inner tank rupture containment basin
  • An array of day tank options such as vent caps, fill caps, float switches, solenoid valves, etc are available to meet the specific requirements for each application

Gallons

Vent

(NPT)

Dimenions (w x d x h) inches
150 % Rupture Basin
Wt 200% Rupture Basin
Wt Double Wall
Wt
25 2" NPT
1.4 1.2 1.1
50 2" NPT 3.0 2.8 2.4
60 2" NPT
75 2" NPT 4.2 3.6 3.2
100 2" NPT 6.2 5.7 5.3
150 2" NPT 7.2 6.8 6.2
200 2" NPT 7.5 7.0 6.4
250 3/4" NPT 8.6 8.5 7.2
275 1" NPT 11.0 10.0 9.5
300

1 1/4" NPT / 

1 1/4" Flg

14.5 13.7 13.0
400

1 1/4" NPT / 

1 1/4" Flg

18.2 17.6 16.4
500

1 1/2" Flg / 

1 1/2" Flg

19.8 18.7 18.0
600

2" Flg / 

1 1/2" Flg

29.5 28.5 27.5
650

2" Flg / 

1 1/2" Flg

38.8 37.8 37.0